Technical specifications 746 ER Z16 Z20 CAT RF
Power supply 230 V~ (+6% -10%) 50 (60) Hz
Electric motor Single – phase, bi - directional
Absorbed power 300 W
Absorbed current 1.5 A
Traction and thrust force 0÷62 daN 0÷50 daN
Motor rotation speed 1.400 rpm
Thermal protection on motor winding 120°C
Clutch Twin – disk in oil bath
Reduction ratio 1:30
Operating ambient temperature 20 °C + 55°C
Weight with oil 14 Kg
Type of oil FAAC oil XD 220
Gate speed 9.6 m/min. 12 m/min.
Protection class IP 44
Dimension
Specifications of 780 D control board
(to be assembled inside the gearmotor)
Transformer Faston connection to the PCB
Power supply 230 Vac (+6%-10%) 50 Hz
Absorbed power 10 W
Motor max. load 1000 W
Accessories max. load 0,5 A
Operating
ambient temperature -20°C +55°C
Fuses 2
Function logics Automatic/"Stepped” automatic
/Semi-automatic/"Stepped” semi-automatic
/Safety/Semi-automatic B/Dead-man C/
Work time Programmable (from 0 to 4 min)
Pause time Programmable (from 0 to 4 min)
Thrust force Adjustable over 50 levels
Terminal board inputs Open - Partially Open - Opening safety devices
Closing safety devices
Stop – Edge - Power supply
On-connector inputs Opening and closing travel-limit/Encoder
Terminal board outputs Flashing lamp/Motor/ 24Vdc power supply
to accessories/ 24Vdc indicator-light-Op.
/cl. Electric lock
Rapid connector Plug-in receiver – Decoding card
Programming Nr. 3 keys(+,-,F) and display,
“basic” or “advanced” mode
"Basic" mode
programmable functions Function logic – Pause time – Thrust force –
Gate direction
"Advanced" mode
programmable functions Thrust torque – Braking – Fail safe –
Pre-flashing – Indicator-light/Timed output/
Op./cl. Electric lock – Opening and closing
safety devices logic – Encoder – Pre and post
limit switch activation slowdown –
Partial opening – Time out –
Cycle counter for maintenance request-
Status indication Display
746 ER Z20 SPECIFICATIONS
Non-reversing Screw gearmotorü Gate max. weight 600 kg. • Gate speed 12 m/min (Z20) and 9.5 m/min (Z16) • Max. use frequency 30% •
Max thrust 50 daN • Electric motor power supply 230 V (+6% - 10%) – 50 (60) Hz • Electric motor power 300 W • Thermal protection at 120 °C
built into motor winding • Operating ambient temperature – 20% + 55°C • Protectin class IP 44 • Lever operated release device with code key •
Single – phase motor with two rotation directions (1.400 rpm) • Pinion gear Z20 / module 4 • Indictive limit – switch • Lower and upper half-body
in die – cast aium with cataphoresis treatment • Twin- disk clutch in oil-bath • Opening/closing force adjustable by hexagonal key • Galvanised
foundation plate with side and height adjustment (optional) • Dimentions (LxWxH) 275x191x336 (mm) • Built-in control board • ABS control board
enclosure •
780D CONTROL BOARD
Transformer: faston connection to the PCB • Power supply: 230 Vac (+6%-10%) 50 Hz • Absorbed power: 10 W • Motor max. load: 1000 W
• Accessories max. load: 0,5 A • Operating ambient temperature: -20°C +55°C • Fuses: 2 • Function logics: Automatic/"Stepped” automatic/
Semi-automatic/"Stepped” semi-automatic/Safety/Semi-automatic B/Dead-man C • Work time: Programmable (from 0 to 4 min) •
Pause time: Programmable (from 0 to 4 min) • Thrust force: Adjustable over 50 levels • Terminal board inputs: Open - Partially Open - Opening
safety devices - Closing safety devices – Stop – Edge - Power supply • On-connector inputs: Opening and closing travel-limit/Encoder • Terminal
board outputs: Flashing lamp/Motor/ 24Vdc power supply to accessories/ 24Vdc indicator-light-Op./cl. Electric lock • Rapid connector: Plugin
receiver – Decoding card • Programming: Nr. 3 keys(+,-,F) and display, “basic” or “advanced” mode • "Basic" mode programmable functions:
Function logic – Pause time – Thrust force – Gate direction • "Advanced" mode programmable functions: Thrust torque – Braking – Fail
safe – Pre-flashing – Indicator-light/Timed output/ Op./cl. Electric lock – Opening and closing safety devices logic – Encoder – Pre and post limit
switch activation slowdown – Partial opening – Time out – Cycle counter for maintenance request • Status indication: Display
|